MMU: Improve unload handling when print is aborted
- Don't allow re-heating the nozzle or the MMU to unload the filament if the print was aborted by a temperature error - Allow MMU to unload filament if there is no temperature error, and there is no fan error when Fan check is enabled - When Fan check is disabled, the MMU may unload if there is no temperature error Change in memory: Flash: +14 bytes SRAM: 0 bytes PFW-1557
This commit is contained in:
parent
52ac95f082
commit
16dfcfeb9a
|
|
@ -5716,23 +5716,26 @@ void lcd_print_stop_finish()
|
|||
|
||||
// restore the auto hotend state
|
||||
hotendDefaultAutoFanState();
|
||||
}
|
||||
|
||||
if (MMU2::mmu2.Enabled() && MMU2::mmu2.FindaDetectsFilament())
|
||||
{
|
||||
// The print was aborted while when the nozzle was cold:
|
||||
// 1. in a paused state => a partial backup in RAM is always available
|
||||
// 2. after a recoverable thermal/fan error had paused the print => only extruder temperature is saved to RAM
|
||||
if (printingIsPaused())
|
||||
{
|
||||
// Restore temperature saved in ram after pausing print
|
||||
restore_extruder_temperature_from_ram();
|
||||
}
|
||||
if (MMU2::mmu2.Enabled() && MMU2::mmu2.FindaDetectsFilament()
|
||||
#ifdef FANCHECK
|
||||
&& fan_check_error != EFCE_REPORTED
|
||||
#endif //FANCHECK
|
||||
) {
|
||||
// The print was aborted while when the nozzle was cold:
|
||||
// 1. in a paused state => a partial backup in RAM is always available
|
||||
// 2. after a recoverable thermal/fan error had paused the print => only extruder temperature is saved to RAM
|
||||
if (printingIsPaused())
|
||||
{
|
||||
// Restore temperature saved in ram after pausing print
|
||||
restore_extruder_temperature_from_ram();
|
||||
}
|
||||
|
||||
// If the pause state was cleared previously or the target temperature is 0°C in the case
|
||||
// of an unconditional stop. In that scenario we do not want to unload.
|
||||
if (target_temperature[0] >= extrude_min_temp) {
|
||||
MMU2::mmu2.unload(); // M702
|
||||
// If the pause state was cleared previously or the target temperature is 0°C in the case
|
||||
// of an unconditional stop. In that scenario we do not want to unload.
|
||||
if (target_temperature[0] >= extrude_min_temp) {
|
||||
MMU2::mmu2.unload(); // M702
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
|
|
|||
Loading…