Add parameter for magnet compensation

allow to enable/disable magnet compensation when 7x7 is in use.
This commit is contained in:
sarusani 2023-09-14 15:19:04 +02:00
parent f193251977
commit 21c57a1222
1 changed files with 4 additions and 2 deletions

View File

@ -3053,7 +3053,8 @@ static void gcode_G80()
mbl.upsample_3x3(); //interpolation from 3x3 to 7x7 points using largrangian polynomials while using the same array z_values[iy][ix] for storing (just coppying measured data to new destination and interpolating between them)
if (nMeasPoints == 7 && eeprom_read_byte((uint8_t*)EEPROM_MBL_MAGNET_ELIMINATION)) {
uint8_t useMagnetCompensation = code_seen('M') ? code_value_uint8() : eeprom_read_byte((uint8_t*)EEPROM_MBL_MAGNET_ELIMINATION);
if (nMeasPoints == 7 && useMagnetCompensation) {
mbl_magnet_elimination();
}
@ -4882,12 +4883,13 @@ void process_commands()
Default 3x3 grid can be changed on MK2.5/s and MK3/s to 7x7 grid.
#### Usage
G80 [ N | C | O | L | R | F | B | X | Y | W | H ]
G80 [ N | C | O | M | L | R | F | B | X | Y | W | H ]
#### Parameters
- `N` - Number of mesh points on x axis. Default is 3. Valid values are 3 and 7.
- `C` - Probe retry counts. Default 3 max. 10
- `O` - Return to origin. Default 1 (true)
- `M` - Use magnet compensation. Will only be used if number of mesh points is set to 7. Default is value stored in EEPROM. Vaild values are 0 (false) and 1 (ture).
Using the following parameters enables additional "manual" bed leveling correction. Valid values are -100 microns to 100 microns.
#### Additional Parameters