From 8d4176a5309eb27e39e272820598d968fc4abe9f Mon Sep 17 00:00:00 2001 From: 3d-gussner <3d.gussner@gmail.com> Date: Tue, 23 Feb 2021 07:24:33 +0100 Subject: [PATCH] Add "Fan check [On|Off]" menu to tune User can en/disable the fan check during print. This is very useful in case of false positive fan errors to let the user to decide to finish print with "faulty" fan. --- Firmware/ultralcd.cpp | 6 ++---- 1 file changed, 2 insertions(+), 4 deletions(-) diff --git a/Firmware/ultralcd.cpp b/Firmware/ultralcd.cpp index 9960b0f7f..5e5bb0389 100755 --- a/Firmware/ultralcd.cpp +++ b/Firmware/ultralcd.cpp @@ -6973,10 +6973,8 @@ static void lcd_tune_menu() SETTINGS_CUTTER; - if(farm_mode) - { - MENU_ITEM_TOGGLE_P(_T(MSG_FANS_CHECK), fans_check_enabled ? _T(MSG_ON) : _T(MSG_OFF), lcd_set_fan_check); - } + MENU_ITEM_TOGGLE_P(_T(MSG_FANS_CHECK), fans_check_enabled ? _T(MSG_ON) : _T(MSG_OFF), lcd_set_fan_check); + #ifdef TMC2130 if(!farm_mode)