Code cleanup: rename params
This commit is contained in:
parent
d3bb6e5ca5
commit
a9c8bb7dbf
|
|
@ -2825,9 +2825,9 @@ static void gcode_G80()
|
|||
nMeasPoints = 3;
|
||||
}
|
||||
|
||||
uint8_t nProbeRetry = code_seen('C') ? code_value_uint8() : eeprom_read_byte((uint8_t*)EEPROM_MBL_PROBE_NR);
|
||||
if (nProbeRetry > 10) {
|
||||
nProbeRetry = 10;
|
||||
uint8_t nProbeRetryCount = code_seen('C') ? code_value_uint8() : eeprom_read_byte((uint8_t*)EEPROM_MBL_PROBE_NR);
|
||||
if (nProbeRetryCount > 10) {
|
||||
nProbeRetryCount = 10;
|
||||
}
|
||||
|
||||
const float area_min_x = code_seen('X') ? code_value() - x_mesh_density - X_PROBE_OFFSET_FROM_EXTRUDER : -INFINITY;
|
||||
|
|
@ -2933,7 +2933,7 @@ static void gcode_G80()
|
|||
}
|
||||
|
||||
// Go down until endstop is hit
|
||||
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetry)) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
|
||||
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetryCount )) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
|
||||
printf_P(_T(MSG_BED_LEVELING_FAILED_POINT_LOW));
|
||||
break;
|
||||
}
|
||||
|
|
@ -2942,7 +2942,7 @@ static void gcode_G80()
|
|||
plan_buffer_line_curposXYZE(Z_LIFT_FEEDRATE);
|
||||
st_synchronize();
|
||||
|
||||
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetry)) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
|
||||
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetryCount )) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
|
||||
printf_P(_T(MSG_BED_LEVELING_FAILED_POINT_LOW));
|
||||
break;
|
||||
}
|
||||
|
|
@ -4886,7 +4886,7 @@ void process_commands()
|
|||
|
||||
#### Parameters
|
||||
- `N` - Number of mesh points on x axis. Default is 3. Valid values are 3 and 7.
|
||||
- `C` - Probe retries. Default 3 max. 10
|
||||
- `C` - Probe retry counts. Default 3 max. 10
|
||||
- `O` - Return to origin. Default 1 (true)
|
||||
|
||||
Using the following parameters enables additional "manual" bed leveling correction. Valid values are -100 microns to 100 microns.
|
||||
|
|
|
|||
Loading…
Reference in New Issue