diff --git a/Firmware/Dcodes.cpp b/Firmware/Dcodes.cpp index 9302f4ac9..0a07593e1 100644 --- a/Firmware/Dcodes.cpp +++ b/Firmware/Dcodes.cpp @@ -598,7 +598,7 @@ void dcode_9() void dcode_10() {//Tell the printer that XYZ calibration went OK LOG("D10 - XYZ calibration = OK\n"); - calibration_status_store(CALIBRATION_STATUS_LIVE_ADJUST); + calibration_status_set(CALIBRATION_STATUS_XYZ); } /*! diff --git a/Firmware/Marlin_main.cpp b/Firmware/Marlin_main.cpp index 1f6e205d5..6d3f3d26b 100644 --- a/Firmware/Marlin_main.cpp +++ b/Firmware/Marlin_main.cpp @@ -3369,13 +3369,8 @@ bool gcode_M45(bool onlyZ, int8_t verbosity_level) bool result = sample_mesh_and_store_reference(); if (result) { - if (calibration_status() == CALIBRATION_STATUS_Z_CALIBRATION) - { - // Shipped, the nozzle height has been set already. The user can start printing now. - calibration_status_store(CALIBRATION_STATUS_CALIBRATED); - } - final_result = true; - // babystep_apply(); + calibration_status_set(CALIBRATION_STATUS_Z); + final_result = true; } } else @@ -3422,14 +3417,10 @@ bool gcode_M45(bool onlyZ, int8_t verbosity_level) lcd_bed_calibration_show_result(result, point_too_far_mask); if (result >= 0) { -#ifdef TEMP_MODEL - calibration_status_store(CALIBRATION_STATUS_TEMP_MODEL_CALIBRATION); - if (eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE) != 1) lcd_show_fullscreen_message_and_wait_P(_T(MSG_TM_NOT_CAL)); -#else // Calibration valid, the machine should be able to print. Advise the user to run the V2Calibration.gcode. - calibration_status_store(CALIBRATION_STATUS_LIVE_ADJUST); - if (eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE) != 1) lcd_show_fullscreen_message_and_wait_P(_T(MSG_BABYSTEP_Z_NOT_SET)); -#endif //TEMP_MODEL + calibration_status_set(CALIBRATION_STATUS_XYZ | CALIBRATION_STATUS_Z); + if (!eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE)) + lcd_show_fullscreen_message_and_wait_P(_T(MSG_BABYSTEP_Z_NOT_SET)); final_result = true; } } @@ -4887,7 +4878,7 @@ eeprom_update_word((uint16_t*)EEPROM_NOZZLE_DIAMETER_uM,0xFFFF); break; } - if (calibration_status() >= CALIBRATION_STATUS_XYZ_CALIBRATION) { + if (!calibration_status_get(CALIBRATION_STATUS_XYZ)) { //we need to know accurate position of first calibration point //if xyz calibration was not performed yet, interrupt temperature calibration and inform user that xyz cal. is needed lcd_show_fullscreen_message_and_wait_P(_i("Please run XYZ calibration first.")); ////MSG_RUN_XYZ c=20 r=4 @@ -5688,7 +5679,9 @@ eeprom_update_word((uint16_t*)EEPROM_NOZZLE_DIAMETER_uM,0xFFFF); eeprom_update_word(reinterpret_cast(&(EEPROM_Sheets_base->s[(eeprom_read_byte(&(EEPROM_Sheets_base->active_sheet)))].z_offset)),0); // Reset the skew and offset in both RAM and EEPROM. + calibration_status_clear(CALIBRATION_STATUS_XYZ); reset_bed_offset_and_skew(); + // Reset world2machine_rotation_and_skew and world2machine_shift, therefore // the planner will not perform any adjustments in the XY plane. // Wait for the motors to stop and update the current position with the absolute values.