From bca0fd81eb6971909aee6a0c4305926e16c381e3 Mon Sep 17 00:00:00 2001 From: Marek Bel Date: Tue, 30 Jul 2019 19:15:33 +0200 Subject: [PATCH] Fix loading filament 255 instead of 0 in first layer calibration wizard. --- Firmware/ultralcd.cpp | 1 + 1 file changed, 1 insertion(+) diff --git a/Firmware/ultralcd.cpp b/Firmware/ultralcd.cpp index acb369d95..6b3880541 100755 --- a/Firmware/ultralcd.cpp +++ b/Firmware/ultralcd.cpp @@ -4798,6 +4798,7 @@ static void lcd_wizard_load() if (mmu_enabled) { lcd_show_fullscreen_message_and_wait_P(_i("Please insert PLA filament to the first tube of MMU, then press the knob to load it."));////c=20 r=8 + tmp_extruder = 0; } else {