Retract, lift Z, move away in XY, disable fan and nozzle heating. Resume nozzle heating.
Known limitations: Doesn't wait for nozzle temperature reaching set temperature before moving to print area. Doesn't resume print fan. Unused code not removed.
This commit is contained in:
parent
af08e16426
commit
d54e629950
|
|
@ -5523,9 +5523,17 @@ static void lcd_test_menu()
|
||||||
static void pause_print()
|
static void pause_print()
|
||||||
{
|
{
|
||||||
stop_and_save_print_to_ram(0.0,0.0);
|
stop_and_save_print_to_ram(0.0,0.0);
|
||||||
|
long_pause();
|
||||||
}
|
}
|
||||||
static void resume_print()
|
static void resume_print()
|
||||||
{
|
{
|
||||||
|
char cmd1[30];
|
||||||
|
strcpy(cmd1, "M104 S");
|
||||||
|
strcat(cmd1, ftostr3(HotendTempBckp));
|
||||||
|
enquecommand(cmd1);
|
||||||
|
strcpy(cmd1, "M109 S");
|
||||||
|
strcat(cmd1, ftostr3(HotendTempBckp));
|
||||||
|
enquecommand(cmd1);
|
||||||
restore_print_from_ram_and_continue(0.0);
|
restore_print_from_ram_and_continue(0.0);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
|
||||||