Add yes-no choice to M862 warning

Fixes #3421

Change in memory:
Flash: -98 bytes
SRAM: 0 bytes
This commit is contained in:
Guðni Már Gilbert 2022-12-13 01:14:40 +00:00 committed by DRracer
parent 54704cb928
commit df65212449
1 changed files with 41 additions and 87 deletions

View File

@ -249,9 +249,6 @@ void update_current_firmware_version_to_eeprom()
eeprom_update_word((uint16_t*)EEPROM_FIRMWARE_VERSION_FLAVOR, (uint16_t)pgm_read_word(&FW_VERSION_NR[3]));
}
#define MSG_PRINT_CHECKING_FAILED_TIMEOUT 30
ClNozzleDiameter oNozzleDiameter=ClNozzleDiameter::_Diameter_400;
ClCheckMode oCheckMode=ClCheckMode::_None;
ClCheckModel oCheckModel=ClCheckModel::_None;
@ -291,6 +288,18 @@ void fCheckModeInit() {
}
}
static void render_M862_warnings(const char* warning, const char* strict, uint8_t check)
{
if (check == 1) { // Warning, stop print if user selects 'No'
if (lcd_show_fullscreen_message_yes_no_and_wait_P(warning)) {
lcd_print_stop();
}
} else if (check == 2) { // Strict, always stop print
lcd_show_fullscreen_message_and_wait_P(strict);
lcd_print_stop();
}
}
void nozzle_diameter_check(uint16_t nDiameter) {
uint16_t nDiameter_um;
@ -305,23 +314,13 @@ void nozzle_diameter_check(uint16_t nDiameter) {
// SERIAL_ECHOLN((float)(nDiameter_um/1000.0));
// SERIAL_ECHOPGM("expected: ");
// SERIAL_ECHOLN((float)(nDiameter/1000.0));
switch (oCheckMode) {
case ClCheckMode::_Warn:
// lcd_show_fullscreen_message_and_wait_P(_i("Printer nozzle diameter differs from the G-code. Continue?"));
lcd_display_message_fullscreen_P(_i("Printer nozzle diameter differs from the G-code. Continue?")); ////MSG_NOZZLE_DIFFERS_CONTINUE c=20 r=5
lcd_wait_for_click_delay(MSG_PRINT_CHECKING_FAILED_TIMEOUT);
//???custom_message_type=CUSTOM_MSG_TYPE_STATUS; // display / status-line recovery
lcd_update_enable(true); // display / status-line recovery
break;
case ClCheckMode::_Strict:
lcd_show_fullscreen_message_and_wait_P(_i(
"Printer nozzle diameter differs from the G-code. Please check the value in settings. Print cancelled.")); ////MSG_NOZZLE_DIFFERS_CANCELLED c=20 r=9
lcd_print_stop();
break;
case ClCheckMode::_None:
case ClCheckMode::_Undef:
break;
}
render_M862_warnings(
_i("Printer nozzle diameter differs from the G-code. Continue?") ////MSG_NOZZLE_DIFFERS_CONTINUE c=20 r=5
,_i("Printer nozzle diameter differs from the G-code. Please check the value in settings. Print cancelled.") ////MSG_NOZZLE_DIFFERS_CANCELLED c=20 r=9
,(uint8_t)oCheckMode
);
if (!farm_mode) {
bSettings = false; // flag ('fake parameter') for 'lcd_hw_setup_menu()' function
menu_submenu(lcd_hw_setup_menu);
@ -339,22 +338,11 @@ void printer_model_check(uint16_t nPrinterModel, uint16_t actualPrinterModel) {
// SERIAL_ECHOLN(actualPrinterModel);
// SERIAL_ECHOPGM("expected: ");
// SERIAL_ECHOLN(nPrinterModel);
switch (oCheckModel) {
case ClCheckModel::_Warn:
// lcd_show_fullscreen_message_and_wait_P(_i("Printer model differs from the G-code. Continue?"));
lcd_display_message_fullscreen_P(_T(MSG_GCODE_DIFF_PRINTER_CONTINUE));
lcd_wait_for_click_delay(MSG_PRINT_CHECKING_FAILED_TIMEOUT);
//???custom_message_type=CUSTOM_MSG_TYPE_STATUS; // display / status-line recovery
lcd_update_enable(true); // display / status-line recovery
break;
case ClCheckModel::_Strict:
lcd_show_fullscreen_message_and_wait_P(_T(MSG_GCODE_DIFF_PRINTER_CANCELLED));
lcd_print_stop();
break;
case ClCheckModel::_None:
case ClCheckModel::_Undef:
break;
}
render_M862_warnings(
_T(MSG_GCODE_DIFF_PRINTER_CONTINUE)
,_T(MSG_GCODE_DIFF_PRINTER_CANCELLED)
,(uint8_t)oCheckModel
);
}
uint8_t mCompareValue(uint16_t nX, uint16_t nY) {
@ -399,23 +387,12 @@ void fw_version_check(const char *pVersion) {
SERIAL_ECHO('.');
SERIAL_ECHOLN(aVersion[3]);
*/
switch (oCheckVersion) {
case ClCheckVersion::_Warn:
// lcd_show_fullscreen_message_and_wait_P(_i("Printer FW version differs from the G-code. Continue?"));
lcd_display_message_fullscreen_P(_i("G-code sliced for a newer firmware. Continue?")); ////MSG_GCODE_NEWER_FIRMWARE_CONTINUE c=20 r=5
lcd_wait_for_click_delay(MSG_PRINT_CHECKING_FAILED_TIMEOUT);
//???custom_message_type=CUSTOM_MSG_TYPE_STATUS; // display / status-line recovery
lcd_update_enable(true); // display / status-line recovery
break;
case ClCheckVersion::_Strict:
lcd_show_fullscreen_message_and_wait_P(
_i("G-code sliced for a newer firmware. Please update the firmware. Print cancelled.")); ////MSG_GCODE_NEWER_FIRMWARE_CANCELLED c=20 r=8
lcd_print_stop();
break;
case ClCheckVersion::_None:
case ClCheckVersion::_Undef:
break;
}
render_M862_warnings(
_i("G-code sliced for a newer firmware. Continue?") ////MSG_GCODE_NEWER_FIRMWARE_CONTINUE c=20 r=5
,_i("G-code sliced for a newer firmware. Please update the firmware. Print cancelled.") ////MSG_GCODE_NEWER_FIRMWARE_CANCELLED c=20 r=8
,(uint8_t)oCheckVersion
);
}
void gcode_level_check(uint16_t nGcodeLevel) {
@ -430,23 +407,12 @@ void gcode_level_check(uint16_t nGcodeLevel) {
// SERIAL_ECHOLN(GCODE_LEVEL);
// SERIAL_ECHOPGM("expected: ");
// SERIAL_ECHOLN(nGcodeLevel);
switch (oCheckGcode) {
case ClCheckGcode::_Warn:
// lcd_show_fullscreen_message_and_wait_P(_i("Printer G-code level differs from the G-code. Continue?"));
lcd_display_message_fullscreen_P(_i("G-code sliced for a different level. Continue?")); ////MSG_GCODE_DIFF_CONTINUE c=20 r=4
lcd_wait_for_click_delay(MSG_PRINT_CHECKING_FAILED_TIMEOUT);
//???custom_message_type=CUSTOM_MSG_TYPE_STATUS; // display / status-line recovery
lcd_update_enable(true); // display / status-line recovery
break;
case ClCheckGcode::_Strict:
lcd_show_fullscreen_message_and_wait_P(
_i("G-code sliced for a different level. Please re-slice the model again. Print cancelled.")); ////MSG_GCODE_DIFF_CANCELLED c=20 r=7
lcd_print_stop();
break;
case ClCheckGcode::_None:
case ClCheckGcode::_Undef:
break;
}
render_M862_warnings(
_i("G-code sliced for a different level. Continue?") ////MSG_GCODE_DIFF_CONTINUE c=20 r=4
,_i("G-code sliced for a different level. Please re-slice the model again. Print cancelled.") ////MSG_GCODE_DIFF_CANCELLED c=20 r=7
,(uint8_t)oCheckGcode
);
}
//-// -> cmdqueue ???
@ -481,23 +447,11 @@ if(pResult != NULL && nLength == nPrinterNameLength) {
if (strncmp_P(pResult, actualPrinterSModel, nLength) == 0) return;
}
switch(oCheckModel)
{
case ClCheckModel::_Warn:
// lcd_show_fullscreen_message_and_wait_P(_i("Printer model differs from the G-code. Continue?"));
lcd_display_message_fullscreen_P(_T(MSG_GCODE_DIFF_PRINTER_CONTINUE));
lcd_wait_for_click_delay(MSG_PRINT_CHECKING_FAILED_TIMEOUT);
//???custom_message_type=CUSTOM_MSG_TYPE_STATUS; // display / status-line recovery
lcd_update_enable(true); // display / status-line recovery
break;
case ClCheckModel::_Strict:
lcd_show_fullscreen_message_and_wait_P(_T(MSG_GCODE_DIFF_PRINTER_CANCELLED));
lcd_print_stop();
break;
case ClCheckModel::_None:
case ClCheckModel::_Undef:
break;
}
render_M862_warnings(
_T(MSG_GCODE_DIFF_PRINTER_CONTINUE)
,_T(MSG_GCODE_DIFF_PRINTER_CANCELLED)
,(uint8_t)oCheckModel
);
}
uint16_t nPrinterType(bool bMMu) {