Sync with upstream

Fix rebase issues
This commit is contained in:
Alex Voinea 2022-07-04 18:55:14 +02:00 committed by 3d-gussner
parent 5e46014359
commit f23e5e57dc
1 changed files with 10 additions and 7 deletions

View File

@ -235,6 +235,7 @@ uint8_t newFanSpeed = 0;
#endif
static bool cancel_heatup = false;
bool CooldownNoWait;
int8_t busy_state = NOT_BUSY;
static long prev_busy_signal_ms = -1;
@ -6046,17 +6047,19 @@ Sigma_Exit:
*/
case 109:
{
CooldownNoWait = false;
LCD_MESSAGERPGM(_T(MSG_HEATING));
heating_status = HeatingStatus::EXTRUDER_HEATING;
heating_status = HeatingStatus::EXTRUDER_HEATING;
prusa_statistics(1);
#ifdef AUTOTEMP
autotemp_enabled=false;
#endif
#endif
if (code_seen('S')) {
setTargetHotend(code_value());
} else if (code_seen('R')) {
setTargetHotend(code_value());
setTargetHotend(code_value());
CooldownNoWait = true;
} else if (code_seen('R')) {
setTargetHotend(code_value());
}
#ifdef AUTOTEMP
if (code_seen('S')) autotemp_min=code_value();
@ -6078,7 +6081,7 @@ Sigma_Exit:
wait_for_heater(codenum, active_extruder); //loops until target temperature is reached
LCD_MESSAGERPGM(_T(MSG_HEATING_COMPLETE));
heating_status = HeatingStatus::EXTRUDER_HEATING_COMPLETE;
heating_status = HeatingStatus::EXTRUDER_HEATING_COMPLETE;
prusa_statistics(2);
//starttime=_millis();
@ -6102,7 +6105,7 @@ Sigma_Exit:
case 190:
#if defined(TEMP_BED_PIN) && TEMP_BED_PIN > -1
{
bool CooldownNoWait = false;
CooldownNoWait = false;
LCD_MESSAGERPGM(_T(MSG_BED_HEATING));
heating_status = HeatingStatus::BED_HEATING;
prusa_statistics(1);