Optimisation: lcd_commands "M702 C" should be "M702"
Change in memory: Flash: -2 bytes SRAM: 0 bytes
This commit is contained in:
parent
0c1052b0da
commit
f49b88c1a1
|
|
@ -964,7 +964,7 @@ void lcd_commands()
|
|||
enquecommand_P(PSTR("M140 S0")); // turn off heatbed
|
||||
enquecommand_P(PSTR("G1 Z10 F1300.000")); //lift Z
|
||||
enquecommand_P(PSTR("G1 X10 Y180 F4000")); //Go to parking position
|
||||
if (MMU2::mmu2.Enabled()) enquecommand_P(PSTR("M702 C")); //unload from nozzle
|
||||
if (MMU2::mmu2.Enabled()) enquecommand_P(PSTR("M702")); //unload from nozzle
|
||||
enquecommand_P(PSTR("M84"));// disable motors
|
||||
forceMenuExpire = true; //if user dont confirm live adjust Z value by pressing the knob, we are saving last value by timeout to status screen
|
||||
lcd_commands_step = 1;
|
||||
|
|
@ -3956,6 +3956,7 @@ static void lcd_wizard_load() {
|
|||
lcd_puts_at_P(0, 2, _T(MSG_LOADING_FILAMENT));
|
||||
loading_flag = true;
|
||||
gcode_M701(FILAMENTCHANGE_FIRSTFEED, 0);
|
||||
//enquecommand_P(PSTR("M701"));
|
||||
}
|
||||
|
||||
bool lcd_autoDepleteEnabled()
|
||||
|
|
|
|||