From faa01b5a5fed0c8e9b35be89e3904fa9a48f606d Mon Sep 17 00:00:00 2001 From: gudnimg Date: Fri, 26 Jul 2024 11:52:20 +0000 Subject: [PATCH] Fix an issue where mFilamentPrompt menu times out Fixes a regression introduced in 3.13.0 here: https://github.com/prusa3d/Prusa-Firmware/commit/a7e9ccfb57e436311cb28b5636b8f66fe7982909#diff-5fbfdca43c192573e31d8e78d255c510fb6e213b118cf38173277ec2a2163880R7462 Before 3.13.0, the menu never timed out until the safety timer turned off the heaters After 3.13.0, the menu times out after 30 seconds. The commit restores pre-3.13.0 behavior --- Firmware/ultralcd.cpp | 1 + 1 file changed, 1 insertion(+) diff --git a/Firmware/ultralcd.cpp b/Firmware/ultralcd.cpp index ca26287a2..354dc819c 100644 --- a/Firmware/ultralcd.cpp +++ b/Firmware/ultralcd.cpp @@ -1815,6 +1815,7 @@ void lcd_print_target_temps_first_line() { static void mFilamentPrompt() { + lcd_timeoutToStatus.stop(); lcd_print_target_temps_first_line(); lcd_puts_at_P(0,1, _T(MSG_PRESS_KNOB)); lcd_set_cursor(0,2);