Simplify status tracking:
- S::Restore to continue to the next logical wizard item
- S::Finish for a successful failure
- S::Failed to exit while showing a failure
We allow resuming from the LCD via start print and resume print,
it makes sense to clear the error on stop too.
For this reason distinguish whether the action is performed
automatically or manually (ie: interactively).
The error is only cleared when the command is run interactively.
In M600 and M702, the Z-lift is taken care of outside this function
so it makes no sense to have a Z-lift within unload_filament()
Only exception to this is in the wizard, there I moved the Z-lift to
happen before we start heating the nozzle.
Change in memory:
Flash: -12 bytes
SRAM: 0 bytes
If during a paused print, the preheat is canceled, keep the bed target temperature
Display bed temperatures only if bed is also heated
Remove not needed variables nTargetOld and nTargetBedOld from the mFilamentItem function
Define new Setting "HeatBedOnLoad" [Yes/No]
It's only used when MESH_BED_LEVELING is not defined. According to
the configuration files, all printers supported use MESH_BED_LEVELING.
So I think we are safe in removing this dead code.
- Dependent on current MMU error being processed
- Includes rename of LEFT_BUTTON_CHOICE -> LCD_LEFT_BUTTON_CHOICE (and right, middle as well) to avoid confusion with MMU buttons' ordering
To render the thermometer and degree symbols
the CGRAM table will instead swap out
the feedrate and clock symbol when
lcd_set_custom_characters_nextpage()
is called.
- combined lcd_show_three_choices_prompt_P and lcd_show_two_choices_prompt_P into one function called lcd_show_choices_prompt_P
- Removed third_col parameter
- Added an enum to make the button selection result more readable
- Rename lcd_show_multiscreen_message_two_choices_and_wait_P to lcd_show_multiscreen_message_with_choices_and_wait_P
- Move MMU error screen from ReportError() to ReportErrorHook()
- Fix the menu selection to work for menus with either two choices or three choices
- The buttons shown on the MMU error menu are now determined by the definition of btnOperation[]
Add an additional parameter to control the position of second choice
prompt position (while defaulting to the old).
This allows Yes/No prompts to be equally spaced.
Add a new LCD_MESSAGE_INFO priority which can be overridden by regular
status updates, but only if a certain amount of time has passed.
Assign a time stamp to all message updates, so that the time since the
last update can be determined. Also switch the message type to Status,
so that the message always becomes visibile.
Always show status or info messages when printing via SD if the message
is recent enough.
If M117 is called before M601 then we would like the custom message to
be visible on the LCD screen until the print is resumed.
Change in memory: +10 bytes of flash
Fixes#3316
01234567890123456789
Temp. cal. [Off] old
PINDA cal. [Off] new
Temp. cal. 1/6 old
PINDA cal. 1/6 new
MSG_TEMP_CALIBRATION -> MSG_PINDA_CALIBRATION
MSG_TEMP_CALIBRATION_DONE -> MSG_PINDA_CALIBRATION_DONE
Updated text
- MSG_PINDA_CALIBRATION_DONE
- MSG_PINDA_CAL_FAILED
Update status line during PINDA cal.
Changed PINDA cal. from submenu to function
- Deleted `lcd_pinda_calibration_menu()`
- Deleted `#MSG_CALIBRATE_PINDA c=17`
Tried to update translations
Updated po files