- Rename lcd_show_multiscreen_message_two_choices_and_wait_P to lcd_show_multiscreen_message_with_choices_and_wait_P
- Move MMU error screen from ReportError() to ReportErrorHook()
- Fix the menu selection to work for menus with either two choices or three choices
- The buttons shown on the MMU error menu are now determined by the definition of btnOperation[]
Such that:
MMU2:E=32766ErrorTitleTextDescription
Becomes:
MMU2:E=32766 ErrorTitle TextDescription
Also simplified the process of combining ErrorTitle and TextDescription
into the msg buffer by using snprintf. This is saver since we only
use dstSize in one place instead of two.
This could cause the printer to crash. The Serial Stream would show
a garbled string.
Also included in this commit:
* The buffer size is increased from 64 bytes to 192 bytes. We need to
take into account the length of the ErrorTitle and ErrorDescription.
* Fix overwrite in ErrorCode message buffer.
When snprintf() if called we need to read the return value to see how
many bytes were written. Then when we call strncpy_P() through
TranslateProgress(), we need to tell the code to start writing
at byte 'len', or &msg[len]. Also we need to update the byte size
which strncpy_P() is allowed to write (64 - len).