Commit Graph

523 Commits

Author SHA1 Message Date
3d-gussner 619d4f0cc9 Merge branch 'MK3' into MK3-private_build 2018-02-05 18:19:18 +01:00
PavelSindler 33aa3d5e7d commint nr 2018-02-05 16:56:31 +01:00
PavelSindler 3bd892135a erase eeprom section which belongs to M500 gcode in case that version was changed and default settings are used 2018-02-05 16:49:06 +01:00
3d-gussner 2dca6efa94 Merge branch 'MK3' into MK3-private_build
Fixed merging
2018-02-03 07:37:14 +01:00
3d-gussner e3b4015ddc Merge branch 'MK3-Hyperfine' into MK3-private_build
Fixed merging
2018-02-03 07:33:34 +01:00
PavelSindler 36536044f4 version changed 2018-02-02 17:48:02 +01:00
Robert Pelnar 4d8807e924 bugfix - failstats (total counters) reset to zero for empty eeprom (0xff) 2018-02-02 15:59:37 +01:00
PavelSindler 2dd2c971e2 whitespace 2018-02-01 20:25:19 +01:00
PavelSindler 84f7d057f3 fw version check: FW_VERSION string is case insensitive (parsing RC works) 2018-02-01 20:23:45 +01:00
PavelSindler d92f6292aa unload with lowered current 2018-02-01 17:43:03 +01:00
PavelSindler a256a8ff19
Merge pull request #450 from XPila/3.1.1-RC6
filament sensor additional check after runout (3mm back, 3mm forward …
2018-02-01 12:20:59 +01:00
Robert Pelnar e20ee149b0 filament sensor additional check after runout (3mm back, 3mm forward @200mm/min) 2018-01-31 21:10:41 +01:00
PavelSindler 9d8191323b
Merge pull request #440 from XPila/3.1.1-RC6
Extruder stealthChop and constant-off-time mode.
2018-01-31 20:21:02 +01:00
XPila 822dd8ff9c
Merge pull request #448 from PavelSindler/eeprom_versions
EEPROM version change: inform user on LCD that default settings were loaded
2018-01-31 20:06:19 +01:00
XPila beb3a507d3
Merge pull request #441 from PavelSindler/send_OK
PID cal. is not sending OK periodically, print fan error pauses print…
2018-01-31 20:03:08 +01:00
Robert Pelnar adc69eda18 PINDA temp. calibration warning messages. 2018-01-31 17:03:33 +01:00
Robert Pelnar 1a01282e33 cardreader - new member "paused"
tmc2130 - decreased crash sensitivity for Y
2018-01-31 15:20:27 +01:00
Robert Pelnar 4c5618c371 failstats - reset "last print" counters
card - new member variable "paused" (bool)
2018-01-31 15:09:36 +01:00
Robert Pelnar daaac2fb88 fail stats 2018-01-30 19:49:40 +01:00
Robert Pelnar 210b97d16d New fail stats (global, last print), crashdetection X and Y separated 2018-01-30 13:10:36 +01:00
PavelSindler 88f248cb77 Inform user that hardcoded default settings were loaded (EEPROM version change) 2018-01-30 11:31:44 +01:00
3d-gussner 3d36273fc6 Minor typo 2018-01-28 08:29:17 +01:00
3d-gussner 837263f6a6 change fimrware name 2018-01-28 08:25:19 +01:00
3d-gussner 1322b2cb70
Merge pull request #44 from 3d-gussner/MK3-PINDA2CalibrationFix
Mk3 pinda2 calibration fix
2018-01-28 08:17:48 +01:00
3d-gussner ea82cb6794 Bug fixed, Manual bed correction "BACK" works again 2018-01-27 18:33:14 +01:00
PavelSindler cbcfcee48f PID cal. is not sending OK periodically, print fan error pauses print in octoprint (not disconnecting), initialize serial line when swithing in settings menu 2018-01-25 15:23:11 +01:00
3d-gussner 6569dd2688 renamed hex file 2018-01-25 13:24:41 +01:00
3d-gussner 511d5d7e82 Merge remote-tracking branch 'upstream/MK3' into MK3-Hyperfine 2018-01-25 12:49:34 +01:00
Robert Pelnar 39bd5c3a1d Extruder stealthChop and constant-off-time mode.
Extruder different chopper frequency in spreadcycle.
Dcodes (fix)
2018-01-25 05:13:21 +01:00
TheZeroBeast f4073120ef -m Added Encoder Fix changes 2018-01-25 06:49:28 +10:00
3d-gussner a2e0a0a02d Hyperfine Bed Tuning for MK3
Changed Bed correction from 4 points to 8 to get better results as we got on the MK2/s
Changed langtool.pl to have EN as default
Added tiem and credentials to support info
2018-01-24 09:45:23 +01:00
Robert Pelnar cae68d9f6d Extruder resolution changed to 32usteps
build 151
2018-01-24 01:41:42 +01:00
XPila 556205d993
Merge pull request #432 from PavelSindler/invalid_gcodes
invalid / unknown gcodes reported on serial
2018-01-24 00:12:47 +01:00
XPila 975ed14cb6
Merge pull request #431 from PavelSindler/fan_error_resume
SD card long pause update
2018-01-24 00:12:33 +01:00
XPila 110ab8b2f6
Merge pull request #426 from PavelSindler/temperatures_update
Preheat temperatures update
2018-01-24 00:11:59 +01:00
XPila b2ba72ffcd
Merge pull request #411 from PavelSindler/typo_fixed
typo fixed
2018-01-24 00:10:28 +01:00
XPila 777dcf072b
Merge pull request #430 from bubnikv/MK3_fsensor_fullrate
Optimization of the filament sensor.
2018-01-24 00:10:00 +01:00
PavelSindler 70ff22571f minor change 2018-01-23 20:04:18 +01:00
PavelSindler 3adedb558b invalid / unknown codes reported on serial 2018-01-23 20:01:02 +01:00
PavelSindler 64a709c097 removed temporary debuging code 2018-01-23 19:14:52 +01:00
PavelSindler 05e0abbd9d startFileprint delayed 2018-01-23 19:11:04 +01:00
bubnikv 44dc12005f Optimization of the filament sensor. 2018-01-23 16:47:42 +01:00
PavelSindler c38458eb67 init 2018-01-23 16:21:43 +01:00
XPila 09e0c566e8
Merge pull request #420 from bubnikv/MK3_stepper_blocking
Mk3 stepper blocking
2018-01-23 13:15:59 +01:00
bubnikv 69f97e0ec3 Separated the "Unknown" build from the "Development" build.
Documented purpose of the various build types.
2018-01-22 17:41:05 +01:00
PavelSindler 188116cb7e Preheat temperatures update 2018-01-22 16:03:43 +01:00
TheZeroBeast a6ef1f76fa
Commit Number brought back inline with upstream 2018-01-21 20:20:12 +10:00
TheZeroBeast cc7b252424
PINDA2 Offset Tuning. Safety features setup
As per the below investigation I have tuned and tested a more robust PINDA2 Offset Calibration.


PINDA2 Investigation

Test #2 (20th Jan 2018)
Moved PINDA2 Thermistor Cal to bed centre
Moved it closer to bed from 150um to 50um
bumped bed up 5C each cycle as it wasn’t heating PINDA2 to temp at current settings

Results from a cool of 35C start

Recv: D8 - Read/Write PINDA
Recv: cal_status=1
Recv: temp_pinda=35C temp_shift=0um
Recv: temp_pinda=40C temp_shift=0um
Recv: temp_pinda=45C temp_shift=30um
Recv: temp_pinda=50C temp_shift=105um
Recv: temp_pinda=55C temp_shift=187um
Recv: temp_pinda=60C temp_shift=350um

Test #3 (21st Jan 2018)
Moved PINDA2 Thermistor Cal to bed centre with measure in default firmware position.
Moved it closer to bed from 150um to 50um
bumped bed up 5C each cycle as it wasn’t heating PINDA2 to temp at current settings and toped at 115 for bed temp
Enabled 255 hotend for test
Made test points [30, 37, 44, 51, 58, 65]

Results from a cool of 30C start

Recv: D8 - Read/Write PINDA
Recv: cal_status=1
Recv: temp_pinda=30C temp_shift=0um
Recv: temp_pinda=37C temp_shift=0um
Recv: temp_pinda=44C temp_shift=60um
Recv: temp_pinda=51C temp_shift=170um
Recv: temp_pinda=58C temp_shift=337um
Recv: temp_pinda=65C temp_shift=645um

Test #4 (21st Jan 2018)
Moved PINDA2 Thermistor Cal to bed centre (for all but first probe by mistake) with measure in default firmware position.
Moved it closer to bed from 150um to 100um
bumped bed up 5C each cycle as it wasn’t heating PINDA2 to temp at current settings and toped at 115 for bed temp
Enabled 255 hotend for test
Made test points [35, 42, 49, 56, 63, 70]
Modified the start skipping code to pickup at additional first point that was being missed

Results from a cool of 33C start

Recv: D8 - Read/Write PINDA
Recv: cal_status=1
Recv: temp_pinda=35C temp_shift=0um
Recv: temp_pinda=42C temp_shift=0um
Recv: temp_pinda=49C temp_shift=97um
Recv: temp_pinda=56C temp_shift=215um
Recv: temp_pinda=63C temp_shift=487um
Recv: temp_pinda=70C temp_shift=815umTest #5 (21st Jan 2018)
Moved PINDA2 Thermistor probe to bed centre
Moved it closer to bed from 150um to 100um
bumped bed up 5C each cycle as it wasn’t heating PINDA2 to temp at current settings and toped at 115 for bed temp
Enabled 255 hotend for test
Made test points [35, 42, 49, 56, 63, 70]
Modified the start skipping code to pickup at additional first point that was being missed

Results from a cool of 32C start

Recv: D8 - Read/Write PINDA
Recv: cal_status=1
Recv: temp_pinda=35C temp_shift=0um
Recv: temp_pinda=42C temp_shift=32753um   WTF?? Actual when probed was -30um
Recv: temp_pinda=49C temp_shift=82um
Recv: temp_pinda=56C temp_shift=200um
Recv: temp_pinda=63C temp_shift=450um
Recv: temp_pinda=70C temp_shift=835um

Send: G75
Recv: 35  0um
Recv: 36  0um
Recv: 37  0um
Recv: 38  0um
Recv: 39  0um
Recv: 40  0um
Recv: 41  0um
Recv: 42  0um
Recv: 43  0um
Recv: 44  4um
Recv: 45  18um
Recv: 46  33um
Recv: 47  50um
Recv: 48  66um
Recv: 49  82um
Recv: 50  97um
Recv: 51  111um
Recv: 52  126um
Recv: 53  141um
Recv: 54  158um
Recv: 55  178um
Recv: 56  200um
Recv: 57  225um
Recv: 58  254um
Recv: 59  286um
Recv: 60  322um
Recv: 61  361um
Recv: 62  404um
Recv: 63  450um
Recv: 64  498um
Recv: 65  550um
Recv: 66  604um
Recv: 67  660um
Recv: 68  718um
Recv: 69  776um
Recv: 70  835um
Recv: 71  893um
Recv: 72  951um
Recv: 73  1009um
Recv: 74  1065um
Recv: 75  1119um
Recv: 76  1171um
Recv: 77  1220um
Recv: 78  1265um
Recv: 79  1307um
Recv: 80  1345um
Recv: ok

Test #6 (21st Jan 2018)
Moved PINDA2 Thermistor probe to bed centre
Moved it closer to bed from 150um to 100um
bumped bed up 5C each cycle as it wasn’t heating PINDA2 to temp at current settings and toped at 115 for bed temp
Enabled 255 hotend for test
Made test points [35, 42, 49, 56, 63, 70]
Modified the start skipping code to pickup at additional first point that was being missed
Hard limits of 0 - 1.5mm offset return in temp_comp_interpolation()

Results from a cool of 34C start

Recv: D8 - Read/Write PINDA
Recv: cal_status=1
Recv: temp_pinda=35C temp_shift=0um
Recv: temp_pinda=42C temp_shift=32753um   WTF?? Actual when probed was -30um
Recv: temp_pinda=49C temp_shift=82um
Recv: temp_pinda=56C temp_shift=200um
Recv: temp_pinda=63C temp_shift=450um
Recv: temp_pinda=70C temp_shift=835um

Test #7 (21st Jan 2018)
Moved PINDA2 Thermistor probe to bed centre
Moved it closer to bed from 150um to 100um
bumped bed up 5C each cycle as it wasn’t heating PINDA2 to temp at current settings and toped at 115 for bed temp
Enabled 255 hotend for test
Made test points [35, 42, 49, 56, 63, 70]
Modified the start skipping code to pickup at additional first point that was being missed
Hard limits of 0 - 1.5mm offset return in temp_comp_interpolation()
Limit probe readings to be positive to prevent float error as in last test at 42C

Results from a cool of 34C start

Recv: D8 - Read/Write PINDA
Recv: cal_status=1
Recv: temp_pinda=35C temp_shift=0um
Recv: temp_pinda=42C temp_shift=0um
Recv: temp_pinda=49C temp_shift=10um
Recv: temp_pinda=56C temp_shift=112um
Recv: temp_pinda=63C temp_shift=355um
Recv: temp_pinda=70C temp_shift=717um
Test #8 21st Jan 2018
Moved it closer to bed from 150um to 100um
bumped bed up 5C each cycle as it wasn’t heating PINDA2 to temp at current settings and toped at 115 for bed temp
Enabled 255 hotend for test but only for the last two probe times to ensure temp is reached
Made test points [35, 42, 49, 56, 63, 70]
Modified the start skipping code to pickup at additional first point that was being missed
Hard limits of 0 - 1.5mm offset return in temp_comp_interpolation()
Limit probe readings to be positive to prevent float errors as in previous tests

Recv: D8 - Read/Write PINDA
Recv: cal_status=1
Recv: temp_pinda=35C temp_shift=0um
Recv: temp_pinda=42C temp_shift=10um
Recv: temp_pinda=49C temp_shift=62um
Recv: temp_pinda=56C temp_shift=160um
Recv: temp_pinda=63C temp_shift=402um
Recv: temp_pinda=70C temp_shift=710um
2018-01-21 20:11:12 +10:00
TheZeroBeast 07bc6cc0a4
Merge pull request #1 from prusa3d/MK3
Mk3 - Realign with upstream
2018-01-21 20:06:38 +10:00
bubnikv a94e266cf1 Documented CPU load and frequency of the following interrupts:
9.  ISR(INT7_vect) 			- Fan signal interrupt
26. ISR(M_USARTx_RX_vect)	- USB to serial RX
37. ISR(USART1_RX_vect)		- R-PI serial RX
2018-01-20 16:20:51 +01:00