- Dependent on current MMU error being processed
- Includes rename of LEFT_BUTTON_CHOICE -> LCD_LEFT_BUTTON_CHOICE (and right, middle as well) to avoid confusion with MMU buttons' ordering
To render the thermometer and degree symbols
the CGRAM table will instead swap out
the feedrate and clock symbol when
lcd_set_custom_characters_nextpage()
is called.
- combined lcd_show_three_choices_prompt_P and lcd_show_two_choices_prompt_P into one function called lcd_show_choices_prompt_P
- Removed third_col parameter
- Added an enum to make the button selection result more readable
- Rename lcd_show_multiscreen_message_two_choices_and_wait_P to lcd_show_multiscreen_message_with_choices_and_wait_P
- Move MMU error screen from ReportError() to ReportErrorHook()
- Fix the menu selection to work for menus with either two choices or three choices
- The buttons shown on the MMU error menu are now determined by the definition of btnOperation[]
Add an additional parameter to control the position of second choice
prompt position (while defaulting to the old).
This allows Yes/No prompts to be equally spaced.
Add a new LCD_MESSAGE_INFO priority which can be overridden by regular
status updates, but only if a certain amount of time has passed.
Assign a time stamp to all message updates, so that the time since the
last update can be determined. Also switch the message type to Status,
so that the message always becomes visibile.
Always show status or info messages when printing via SD if the message
is recent enough.
If M117 is called before M601 then we would like the custom message to
be visible on the LCD screen until the print is resumed.
Change in memory: +10 bytes of flash
Fixes#3316
01234567890123456789
Temp. cal. [Off] old
PINDA cal. [Off] new
Temp. cal. 1/6 old
PINDA cal. 1/6 new
MSG_TEMP_CALIBRATION -> MSG_PINDA_CALIBRATION
MSG_TEMP_CALIBRATION_DONE -> MSG_PINDA_CALIBRATION_DONE
Updated text
- MSG_PINDA_CALIBRATION_DONE
- MSG_PINDA_CAL_FAILED
Update status line during PINDA cal.
Changed PINDA cal. from submenu to function
- Deleted `lcd_pinda_calibration_menu()`
- Deleted `#MSG_CALIBRATE_PINDA c=17`
Tried to update translations
Updated po files
Split off yes/no lcd handling from
lcd_show_fullscreen_message_yes_no_and_wait_P into a separate function
in order to allow generic requests where the text prompt can change.
Use the internal lcd_status_message_level for multiple severity levels
of alert messages.
This is needed to distinguish between non-critical alerts (such as FAN
ERROR) from critical ones (any heater issue). During a failure
scenario, a critical error MUST NOT be overridden by a lower-level one.
As such LCD_STATUS_CRITICAL is currently used for all heater-related
errors that result in a safety full-stop.