dda.c: don't set timer twice when going from one move to the next.
This is a bug which existed, well, basically forever. Nobody noticed until precision timings could be recorded with SimulAVR.
This commit is contained in:
parent
68cc213a70
commit
c594af3e19
7
dda.c
7
dda.c
|
|
@ -659,10 +659,11 @@ void dda_step(DDA *dda) {
|
||||||
// z stepper is only enabled while moving
|
// z stepper is only enabled while moving
|
||||||
z_disable();
|
z_disable();
|
||||||
}
|
}
|
||||||
else
|
else {
|
||||||
psu_timeout = 0;
|
psu_timeout = 0;
|
||||||
|
// After having finished, dda_start() will set the timer.
|
||||||
setTimer(dda->c >> 8);
|
setTimer(dda->c >> 8);
|
||||||
|
}
|
||||||
|
|
||||||
// turn off step outputs, hopefully they've been on long enough by now to register with the drivers
|
// turn off step outputs, hopefully they've been on long enough by now to register with the drivers
|
||||||
// if not, too bad. or insert a (very!) small delay here, or fire up a spare timer or something.
|
// if not, too bad. or insert a (very!) small delay here, or fire up a spare timer or something.
|
||||||
|
|
|
||||||