Resume hotend temperature if parked + MMU restarted
PFW-1355
This commit is contained in:
parent
01c1f4a8dd
commit
84d9eee61d
|
|
@ -349,6 +349,12 @@ void MMU2::ToolChangeCommon(uint8_t slot){
|
|||
break;
|
||||
// otherwise: failed to perform the command - unload first and then let it run again
|
||||
IncrementMMUFails();
|
||||
|
||||
// just in case we stood in an error screen for too long and the hotend got cold
|
||||
ResumeHotendTemp();
|
||||
// if the extruder has been parked, it will get unparked once the ToolChange command finishes OK
|
||||
// - so no ResumeUnpark() at this spot
|
||||
|
||||
unload();
|
||||
// if we run out of retries, we must do something ... may be raise an error screen and allow the user to do something
|
||||
// but honestly - if the MMU restarts during every toolchange,
|
||||
|
|
@ -771,7 +777,7 @@ bool MMU2::manage_response(const bool move_axes, const bool turn_off_nozzle) {
|
|||
if (!nozzleTimeout.running()){
|
||||
nozzleTimeout.start();
|
||||
LogEchoEvent_P(PSTR("Cooling Timeout started"));
|
||||
} else if (nozzleTimeout.expired(DEFAULT_SAFETYTIMER_TIME_MINS*60*1000ul)){ // mins->msec. TODO: do we use the global or have our own independent timeout
|
||||
} else if (nozzleTimeout.expired(DEFAULT_SAFETYTIMER_TIME_MINS*60*1000ul)){ // mins->msec.
|
||||
mmu_print_saved &= ~(SavedState::CooldownPending);
|
||||
mmu_print_saved |= SavedState::Cooldown;
|
||||
setAllTargetHotends(0);
|
||||
|
|
|
|||