Merge pull request #4387 from sarusani/MBL_retries

MBL: Rename repeat param from R to C to avoid overlap
This commit is contained in:
3d-gussner 2023-09-14 08:42:54 +02:00 committed by GitHub
commit b652bee808
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 7 additions and 7 deletions

View File

@ -2825,9 +2825,9 @@ static void gcode_G80()
nMeasPoints = 3;
}
uint8_t nProbeRetry = code_seen('R') ? code_value_uint8() : eeprom_read_byte((uint8_t*)EEPROM_MBL_PROBE_NR);
if (nProbeRetry > 10) {
nProbeRetry = 10;
uint8_t nProbeRetryCount = code_seen('C') ? code_value_uint8() : eeprom_read_byte((uint8_t*)EEPROM_MBL_PROBE_NR);
if (nProbeRetryCount > 10) {
nProbeRetryCount = 10;
}
const float area_min_x = code_seen('X') ? code_value() - x_mesh_density - X_PROBE_OFFSET_FROM_EXTRUDER : -INFINITY;
@ -2933,7 +2933,7 @@ static void gcode_G80()
}
// Go down until endstop is hit
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetry)) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetryCount )) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
printf_P(_T(MSG_BED_LEVELING_FAILED_POINT_LOW));
break;
}
@ -2942,7 +2942,7 @@ static void gcode_G80()
plan_buffer_line_curposXYZE(Z_LIFT_FEEDRATE);
st_synchronize();
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetry)) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
if (!find_bed_induction_sensor_point_z(has_z ? z0 - Z_CALIBRATION_THRESHOLD : -10.f, nProbeRetryCount )) { //if we have data from z calibration max allowed difference is 1mm for each point, if we dont have data max difference is 10mm from initial point
printf_P(_T(MSG_BED_LEVELING_FAILED_POINT_LOW));
break;
}
@ -4882,11 +4882,11 @@ void process_commands()
Default 3x3 grid can be changed on MK2.5/s and MK3/s to 7x7 grid.
#### Usage
G80 [ N | R | L | R | F | B | X | Y | W | H ]
G80 [ N | C | O | L | R | F | B | X | Y | W | H ]
#### Parameters
- `N` - Number of mesh points on x axis. Default is 3. Valid values are 3 and 7.
- `R` - Probe retries. Default 3 max. 10
- `C` - Probe retry counts. Default 3 max. 10
- `O` - Return to origin. Default 1 (true)
Using the following parameters enables additional "manual" bed leveling correction. Valid values are -100 microns to 100 microns.