Commit Graph

1573 Commits

Author SHA1 Message Date
D.R.racer 2e293e90a0 MMU2 interface overhaul
First port of the new MMU2-printer interface into 8bit FW.
2022-09-16 10:21:53 +02:00
Alex Voinea c27e4623c5 Fix build (??) 2022-09-16 10:20:32 +02:00
Alex Voinea 329745368e Improve PAT9125 UI implementation 2022-09-16 10:20:32 +02:00
Alex Voinea 340bc87110 Checkpoint: jam detection 2022-09-16 10:20:32 +02:00
Alex Voinea f9ff929bbe Enable fsensor when preparing for shipping 2022-09-16 10:17:04 +02:00
Alex Voinea 5484882758 Checkpoint after a lot of removal 2022-09-16 10:17:04 +02:00
Alex Voinea fc49ba115a Move more IR sensor analog stuff to Filament_sensor.h 2022-09-16 10:09:20 +02:00
Alex Voinea 7224b5c2b6 Remove OQ and add fancy autoload interaction 2022-09-16 10:08:39 +02:00
Alex Voinea d84e6bda63 Remove old fsensor init 2022-09-16 10:07:49 +02:00
Alex Voinea 45e43137a5 Filament sensor refactoring initial 2022-09-16 10:07:49 +02:00
3d-gussner 270a1086ab No translation needed 2022-09-14 11:33:24 +02:00
3d-gussner 0a68de0bbe Update MSG c=xx
Mark unused strings as `_n`
2022-09-14 11:33:24 +02:00
Alex Voinea 510f13b24a Make the diag pins open collector with pullup.
Solves random crash detected on startup
2022-09-14 07:39:47 +02:00
D.R.racer 996f9943a1 Extract PRINTER_ACTIVE into a noinline function
Having the original PRINTER_ACTIVE macro copied at multiple spots doesn't make sense.
Refactoring it into a non-inline function saved ~400 bytes of code.
It should be safe in terms of performance, all occurrences are at non-time critical spots.
2022-09-14 07:31:39 +02:00
Yuri D'Elia d78506a8ea TM: Rename D70 I to D70 S for consistency with M310 S 2022-09-02 15:59:29 +02:00
Yuri D'Elia 10c524fdb3 TM: Add M310 [F] parameter to enable autotune self-test 2022-09-02 15:59:29 +02:00
Yuri D'Elia 9b5ef75b68 Correctly translate thermal model LCD messages 2022-09-02 15:59:29 +02:00
Alex Voinea 39eb728d54 More farm optimizations
Kudos @gudnimg
2022-08-30 13:57:43 +02:00
Alex Voinea d1c30c338f Fix farmless mode 2022-08-30 13:57:43 +02:00
Alex Voinea bef7b086e3 Isolate the entire farm and statistics code 2022-08-30 13:57:43 +02:00
Alex Voinea 7d597eb8b0 Move farm mode to separate file 2022-08-30 13:57:43 +02:00
Alex Voinea 4e7d686b83
Merge pull request #3574 from leptun/extra_optimizations
More optimizations for 3.12 to fit
2022-08-29 19:25:46 +03:00
Alex Voinea 692f51c51e Save target bed temperature, not current temperature 2022-08-28 11:21:17 +03:00
Guðni Már Gilbert 7d86a0d121 Reduce a few magic numbers for FILENAME_LENGTH
flash: 0
RAM: 0
2022-08-26 19:26:26 +03:00
Guðni Már Gilbert 22582e560e Remove one redundant st_synchronize() call
flash: -4
RAM: 0

st_synchronize() is called just before leaving gcode_G28() so we don't need to call it again just after leaving gcode_G28()
2022-08-26 19:25:07 +03:00
Alex Voinea 25350dfbbc Remove unused variable bFilamentFirstRun
flash: 0
RAM: -1
2022-08-26 19:14:40 +03:00
Guðni Már Gilbert f7ae3039f8 Don't include M851 in build if Auto Bed Leveling is not enabled
The variable cs.zprobe_zoffset is not used unless
auto bed leveling is enabled
2022-08-26 15:35:28 +00:00
Alex Voinea 78534f3b48 Start at the first segment, not the last segment 2022-08-24 20:19:26 +03:00
Alex Voinea 671519caf3 Optimize by hand since the lto is still stooopit
saves ~100B
2022-08-24 20:19:26 +03:00
Alex Voinea b27c8b50e0 Fix power panic handling 2022-08-24 20:19:26 +03:00
Alex Voinea 05bd1ba57f Multi-segment pause resume initial 2022-08-24 20:19:26 +03:00
DRracer 0933fdb6fe
Merge pull request #3552 from wavexx/temp_model_check
Thermal Model protection
2022-08-24 19:16:48 +02:00
Yuri D'Elia 7cd888cd0a Update documentation of ThermalStop() 2022-08-21 15:22:46 +02:00
DRracer 3ebd8b88a4
Merge pull request #3486 from gudnimg/gudni-optimisation
Flash optimizations in loop() and status screen menu
2022-08-19 17:21:17 +02:00
DRracer 0a8d2a3224
Merge pull request #3456 from wavexx/filament_load_consistency
Cleanup: use more constants in M701
2022-08-19 17:14:54 +02:00
DRracer 84888507e3
Merge pull request #3557 from wavexx/fix_g28_code_value
G28: check for X/Y/Z parameters before calling code_value_long
2022-08-19 17:12:07 +02:00
Yuri D'Elia 06d19b472a G28: check for X/Y/Z parameters before calling code_value_long
Fixes #3555, thanks to @toombaumarkt
2022-08-07 00:36:54 +02:00
Yuri D'Elia 68c04ca2f6 Switch a few pointers that don't manipute strings to const 2022-08-06 23:08:03 +02:00
Yuri D'Elia a533ba3574 Reset sdpos_atomic when starting a new SD print
Fix an incorrect SD offset on the first G-Code command when the second
SD print is started.
2022-08-06 22:16:50 +02:00
3d-gussner 8cbe69e285 Update RepRap documentation 2022-08-02 17:56:53 +02:00
Guðni Már Gilbert 33a0a58810 Optimise manage_inactivity call in loop()
Saves 12 bytes of flash
2022-07-27 11:14:17 +00:00
Yuri D'Elia c5c2557c5e Improve M310 documentation 2022-07-25 17:30:22 +02:00
Yuri D'Elia 374b829fb6 Generalize menu_block_entering_on_serious_errors for menu lockout
Call this variable menu_block_mask instead. We don't need to know the
exact reason of why we're locking the menu.

We will be able to reuse this to prevent menu entry during more
activities in a cleaner way than testing for each condition as it's
currently done for both menu entry and longpress.
2022-07-25 17:30:22 +02:00
Yuri D'Elia cb3fec5cac Improve M310 documentation 2022-07-25 17:30:22 +02:00
Yuri D'Elia 39ad53ab11 Simplify fan checks now that lcd pause works correctly 2022-07-25 17:30:22 +02:00
Yuri D'Elia 1eb7871bab Also save fan speeds during a thermal error pause
Similarly to temperatures, the fan speed is overwritten and needs to be
restored appropriately.
2022-07-25 17:30:22 +02:00
Yuri D'Elia eccfcd7424 Save/restore temperatures during a thermal pause
Re-used saved_* vars (as normally used during the paused state) to
backup the original values when a thermal error occurs.
2022-07-25 17:30:22 +02:00
Yuri D'Elia 63dab63f2e uvlo: Never wait for bed temperature when recovering
If the user accepted to resume, do not wait for bed temperature when
recovering. This only adds a pointless delay when recovering a short
pause and doesn't really improve the recovery quality after a long
pause.
2022-07-25 17:30:22 +02:00
Yuri D'Elia 8f02262bbd Save/restore bed temperature during pause
This will be needed during a thermal error pause that disables the bed
as an additional safety precaution.
2022-07-25 17:30:22 +02:00
Yuri D'Elia 9ef80226c9 Rename argument of ThermalStop for clarity 2022-07-25 17:30:22 +02:00