The Extra Loading Distance is configurable by the user.
We need to compensate the hardcoded sequence
such that it does not extrude too much or
too little. Currently the firmware
extrudes too little.
Fixes issue where First Layer Cal. triggers an unload before any
filament is loaded
The purpose of this if() statement is to handle the case where
a user or developer is sending T-codes to the printer directly
via Serial. Such as when one first sends T0 and then T4.
And unload must be triggered in-between, we can do this automatically
if FINDA detect filament.
Change in memory:
Flash: -10 bytes
SRAM: 0 bytes
If there is no running print, and the printer is Stopped, add a new
"Acknowledge error" menu entry to unlock the printer.
This simply calls lcd_print_stop(), which is identical in behavior to a
thermal error with a running print.
Set a menu block for fatal thermal errors instead of abusing
lcd_return_to_status() to kick the user out of the menus.
This now allows a thermal model error to be recoverable through menu
access.
We allow resuming from the LCD via start print and resume print,
it makes sense to clear the error on stop too.
For this reason distinguish whether the action is performed
automatically or manually (ie: interactively).
The error is only cleared when the command is run interactively.
The printer shouldn't continue endlessly asking for a version if an old MMU is detected.
Also if the protocol is supposed to be turned off, it
shouldn't be sending S0 queries.
In M600 and M702, the Z-lift is taken care of outside this function
so it makes no sense to have a Z-lift within unload_filament()
Only exception to this is in the wizard, there I moved the Z-lift to
happen before we start heating the nozzle.
Change in memory:
Flash: -12 bytes
SRAM: 0 bytes
Ensure that fan checks are reset and use the new speed at each step of
the calibration.
This also gives extra time to the fan to ramp-up from a cold start,
when a fancheck could previously start right *after* the speed change.
Should fix#3791
Since M310 cannot change the heaters, allowing M310 S0 (and changing
parameters) allows to recover a usb-controlled printer which has been
locked-out due to bad model settings.
This prevents the ability to run gcode from the SD card.
In a thermal error with faulty values, and without serial access, this
is the only way to process an M310 instruction and recover.