Now that lcd_status_message is now initialised correctly at boot-up,
this for-loop is no longer required. Now lcd_status_message is
only set in lcd_updatestatus() which always calls lcd_finishstatus()
lcd_finishstatus() makes sure the message does not exceed 20 characters
Saves 34 bytes of flash
static variables are automatically zero initialised. Now that the
status line message is initialised in ultralcd_init(), we don't
need to set the variable in global scope.
Saves 22 bytes of flash and 1 byte of SRAM
During first layer calibration we have the live Z baby step menu
on the LCD and the user can tune their Z offset live.
Once the first layer calibration is done, we want to exit the menu
immediately. For this purpose it is much more efficient to
call lcd_return_to_status(). There is no visual difference
on the LCD for the user.
Change in memory footprint:
Flash: -34 bytes
SRAM: -1 byte
The current unload sequence does not give good results.
The Marlin 2 sequence looks good on my end. This can be later
used to improve M600
Added all the constants from Marlin 2
It is only used when the MMU is disabled. With the MMU we use a defined ramming sequence.
When the MMU is disabled I borrowed the usages from Marlin 2.
The L parameter only defines the length for the "fast" load length.
Default value is 70mm, same as M600
Fix the unload procedure when the user has paused a print
then stopped the print after the temperature has reached below 175°C
Now the E-motor will move as expected
- Dependent on current MMU error being processed
- Includes rename of LEFT_BUTTON_CHOICE -> LCD_LEFT_BUTTON_CHOICE (and right, middle as well) to avoid confusion with MMU buttons' ordering
To render the thermometer and degree symbols
the CGRAM table will instead swap out
the feedrate and clock symbol when
lcd_set_custom_characters_nextpage()
is called.
- combined lcd_show_three_choices_prompt_P and lcd_show_two_choices_prompt_P into one function called lcd_show_choices_prompt_P
- Removed third_col parameter
- Added an enum to make the button selection result more readable
- Rename lcd_show_multiscreen_message_two_choices_and_wait_P to lcd_show_multiscreen_message_with_choices_and_wait_P
- Move MMU error screen from ReportError() to ReportErrorHook()
- Fix the menu selection to work for menus with either two choices or three choices
- The buttons shown on the MMU error menu are now determined by the definition of btnOperation[]
makes the code a bit shorter as well, because the compiler can be sure
that the variables are not accessed from the outside of the
fsensor.cpp compilation unit.
Having the original PRINTER_ACTIVE macro copied at multiple spots doesn't make sense.
Refactoring it into a non-inline function saved ~400 bytes of code.
It should be safe in terms of performance, all occurrences are at non-time critical spots.
Add an additional parameter to control the position of second choice
prompt position (while defaulting to the old).
This allows Yes/No prompts to be equally spaced.
Modify lcd_show_multiscreen_message_two_choices_and_wait_P to also
handle single-screen or empty (no-clear) prompts, making other functions
redundant. Saves 76 bytes.
Change existing functions to simply call
lcd_show_multiscreen_message_two_choices_and_wait_P with the correct
arguments.
This changes the prompt of existing Yes/No messages: the previous prompt
would use the last two lines of the LCD, while the new prompt is using
just the last line of the LCD instead.
Translation do not require updates, since the Yes/No translation was
already the same in both implementations.
flash: -22
RAM: 0
menu_lcd_lcdupdate_func() takes care of starting lcd_timeoutToStatus if the knob is clicked.
When the knob is clicked we only want to back out of the menu.