Main changes:
* setAllTargetHotends() is removed
* setTargetHotendSafe() is removed
* Extruder parameter on setTargetHotend() is dropped
Change in memory:
Flash: -192 bytes
SRAM: 0 bytes
During calibration model warnings are possible/normal. This is
apparently leading some into thinking the hotend might be faulty
and abort the calibration with a hard reset.
Disable warnings/beeps during calibration.
Rely on the error threshold only.
During thermal errors all fans are set to full speed.
When the print is resumed or stopped *and* the thermal error is gone,
also restore the autofan state.
Fixes#3893
Running `M310 A` should set the TM calibration bit status if the
autotune procedure was successful.
Partially addresses #3891 and #3890, since running `M310 A F0` should
*still* count as valid calibration data and is not something that can be
replicated by using the LCD (which enforces self-test).
Alert messages are intended to persist above "info" messages, thus
preventing further calibration status updates to be shown (such as
thermal model calibration).
Just set the message as a regular status message.
Fixes#3892
This PR tries to address the 3 different startup scenarios for 1st layer calibration with the MMU:
- 1st lay cal started with correct filament already loaded in the nozzle - we should continue, but skip the first 58mm (first 2 g-codes in the hard coded sequence) of purge line extrusion
- 1st lay cal started with other filament already loaded in the nozzle - we should unload and then issue a toolchange with no extra unload
- 1st lay cal started without loaded filament - we should just do a toolchange with no extra unload
PFW-1457
Update the eeprom FW version as soon as migration is complete, to avoid
resetting the CALIBRATION_V2 variable at each reset.
Do not implicitly reset the calibration steps for WizState::Run: do this
only for the menu action.
Simplify status tracking:
- S::Restore to continue to the next logical wizard item
- S::Finish for a successful failure
- S::Failed to exit while showing a failure
Instead of reading and checking if a character is a whitespace
just print it out onto the LCD. This makes the code a bit less
complex. Whether there is a whitespace character, we always end
up reading from program space, so I doubt this has much performance
impact.
Change in memory:
Flash: -38 bytes
SRAM: 0 bytes
If there is no running print, and the printer is Stopped, add a new
"Acknowledge error" menu entry to unlock the printer.
This simply calls lcd_print_stop(), which is identical in behavior to a
thermal error with a running print.
We allow resuming from the LCD via start print and resume print,
it makes sense to clear the error on stop too.
For this reason distinguish whether the action is performed
automatically or manually (ie: interactively).
The error is only cleared when the command is run interactively.