Simplify the rendering to cover more scenarios:
"[nr.]>?"
"?>?"
Both of these indicate there is a bug in the firmware.
Currently these are not handled and result in the status screen being corrupted.
This is because we are trying to write a 3 digit number
where there is not space on the LCD for it.
Change in memory:
Flash: -52 bytes
SRAM: 0 bytes
It's only used when MESH_BED_LEVELING is not defined. According to
the configuration files, all printers supported use MESH_BED_LEVELING.
So I think we are safe in removing this dead code.
This code was introduced with v3.8.0 but was always disabled.
I propose the code be removed since it has not been enabled
for 3 years since its introduction.
We only need to check if the MMU is enabled once,
no need to do it in every submenu.
This way we save little bit of flash memory.
Change in memory:
Flash: -24 bytes
SRAM: 0 bytes
We can use lcd_print_pad to determine
whether the end of the file name was reached
lcd_print_pad now returns the last character pointed to.
If the end of the string was reached, it will be the null delimeter which
evaluates to "false" in an if statment (same as NULL).
Else "true" means the end of the string was not reached.
Change in memory:
Flash: -42 bytes
SRAM: 0 bytes
ON_MENU_ENTER runs code within the brackets only once
after a new menu is entered.
For the tool change menu, this allows us to display the data and
read from EEPROM only once.
Fixes#3715
When a long-press is triggered, the LCD inactivity timer
needs to be restarted. This is done with lcd_timeoutToStatus.start()
This also fixes situations where a long-press is triggered, and the timer
times out immediately (because it was not reset properly)
Change in memory:
Flash: +8 bytes
SRAM: 0 bytes
So in an ideal scenario, the newest file is first. This of course breaks as soon as a file is deleted/renamed/moved, but it should at least be fixed now compared to before where the direction could be influenced by a disabled setting
The current code forces any warning to return the user to the status
screen in order to show the message.
Thermal anomaly warnings can repeat at very short intervals, making menu
navigation (to pause/tune the print) impossible.
We now check if the message to be displayed is the same and only force a
kickback for new messages.
This partially reverts https://github.com/prusa3d/Prusa-Firmware/pull/3600
since we need the string to be null terminated for ease of comparison.
We pad the status line at display time instead using the new
lcd_print_pad() function which achieves the same effect.
In ultralcd_init() do not use lcd_setstatuspgm() to initialize the
welcome message.
The internal call to lcd_finishstatus() requires the serial to be
already available. Split the function into lcd_padstatus() to pre-pad
the string and save some space.