These functions should be able to be re-used during a power panic
- save_print_file_state
- restore_print_file_state
No functional change at the moment.
We're assigning step_rate with the 16-bit value of final_rate
I would expect the comparison to be 16-bit also then.
Change in memory:
Flash: -32 bytes
SRAM: 0 bytes
The filament is never in the nozzle at this point so there
should be no oozing.
When a single material MMU print, I can hear audible noise
from the motor after executing Tx code. After some timeout
(while the heaters still heating up) I can hear the firmware
disable the E-motor. But we can safely disable it immediately
after the try-load-unload sequence.
Change in memory:
Flash: +4 bytes
SRAM: 0 bytes
Remove a few redundant language.h includes
Also remove language.h include from cmdqueue.h to prevent including language.h unnecessarily
Fix missing message.h includes in a few files
* Sync PEC `FINDA_DIDNT_GO_OFF` to `FINDA_FILAMENT_STUCK`
* Sync PEC `FSENSOR_DIDNT_GO_OFF` to `FSENSOR_FILAMENT_STUCK`
* Sync PEC `PULLEY_STALLED` to `PULLEY_CANNOT_MOVE`
* Sync PEC `SELECTOR_CANNOT_MOVE` update text
* Sync PEC `IDLER_CANNOT_MOVE` update text
* Sync PEC `PULLEY_WARNING_TMC_TOO_HOT` to `WARNING_TMC_PULLEY_TOO_HOT`
* Snyc PEC `RestartMMU` to `ResetMMU`
Also related text
* Sync PEC `SELECTOR_WARNING_TMC_TOO_HOT` to `WARNING_TMC_SELECTOR_TOO_HOT`
* Sync PEC `IDLER_WARNING_TMC_TOO_HOT` to `WARNING_TMC_IDLER_TOO_HOT`
* Sync PEC `PULLEY_TMC_OVERHEAT_ERROR` to `TMC_PULLEY_OVERHEAT_ERROR`
* Sync PEC `SELECTOR_TMC_OVERHEAT_ERROR` to `TMC_SELECTOR_OVERHEAT_ERROR`
* Sync PEC `IDLER_TMC_OVERHEAT_ERROR` to `TMC_IDLER_OVERHEAT_ERROR`
* Sync PEC `PULLEY_TMC_DRIVER_ERROR` to `TMC_PULLEY_DRIVER_ERROR`
Also releated text
* Sync PEC `SELECTOR_TMC_DRIVER_ERROR` to `TMC_SELECTOR_DRIVER_ERROR`
Also related text
* Sync PEC `IDLER_TMC_DRIVER_ERROR` to `TMC_IDLER_DRIVER_ERROR`
Also related text
* Sync PEC `PULLEY_TMC_DRIVER_RESET` to `TMC_PULLEY_DRIVER_RESET`
* Sync PEC `SELECTOR_TMC_DRIVER_RESET` to `TMC_SELECTOR_DRIVER_RESET`
* Sync PEC `IDLER_TMC_DRIVER_RESET` to `TMC_IDLER_DRIVER_RESET`
* Sync PEC `PULLEY_TMC_UNDERVOLTAGE_ERROR` to `TMC_PULLEY_UNDERVOLTAGE_ERROR`
* Sync PEC `SELECTOR_TMC_UNDERVOLTAGE_ERROR` to `TMC_SELECTOR_UNDERVOLTAGE_ERROR`
* Sync PEC `IDLER_TMC_UNDERVOLTAGE_ERROR` to `TMC_IDLER_UNDERVOLTAGE_ERROR`
* Sync PEC `PULLEY_TMC_DRIVER_SHORTED` to `TMC_PULLEY_DRIVER_SHORTED`
Also related text
* Sync PEC `SELECTOR_TMC_DRIVER_SHORTED` to `TMC_SELECTOR_DRIVER_SHORTED`
Also related text
* Sync PEC `IDLER_TMC_DRIVER_SHORTED` to `TMC_IDLER_DRIVER_SHORTED`
Also related text
* Sync PEC `PULLEY_SELFTEST_FAILED` to `MMU_PULLEY_SELFTEST_FAILED`
Also related text
* Sync PEC `SELECTOR_SELFTEST_FAILED` to `MMU_SELECTOR_SELFTEST_FAILED`
Also releated text
* Sync PEC `IDLER_SELFTEST_FAILED` to `MMU_IDLER_SELFTEST_FAILED`
Also related text
* Sync PEC fix MMU_MMU
Update MMU MCU UNDERPOWER
* Sync PEC `FIL_ALREADY_LOADED` to `FILAMENT_ALREADY_LOADED`
Also related text
* Add Prusa Error Codes check script
* Remove `:` at FINDA and FSENSOR as it is in other tiles
* Sync
FSENSOR_DIDNT_TRIGGER
MSG_DESC_SELECTOR_CANNOT_MOVE
MSG_DESC_IDLER_CANNOT_MOVE
MSG_DESC_FW_UPDATE_NEEDED
FILAMENT_ALREADY_LOADED
* Add MMU UNKOWN_ERROR PEC