Simplify status tracking:
- S::Restore to continue to the next logical wizard item
- S::Finish for a successful failure
- S::Failed to exit while showing a failure
Instead of reading and checking if a character is a whitespace
just print it out onto the LCD. This makes the code a bit less
complex. Whether there is a whitespace character, we always end
up reading from program space, so I doubt this has much performance
impact.
Change in memory:
Flash: -38 bytes
SRAM: 0 bytes
If there is no running print, and the printer is Stopped, add a new
"Acknowledge error" menu entry to unlock the printer.
This simply calls lcd_print_stop(), which is identical in behavior to a
thermal error with a running print.
We allow resuming from the LCD via start print and resume print,
it makes sense to clear the error on stop too.
For this reason distinguish whether the action is performed
automatically or manually (ie: interactively).
The error is only cleared when the command is run interactively.
In M600 and M702, the Z-lift is taken care of outside this function
so it makes no sense to have a Z-lift within unload_filament()
Only exception to this is in the wizard, there I moved the Z-lift to
happen before we start heating the nozzle.
Change in memory:
Flash: -12 bytes
SRAM: 0 bytes
- Correctly sequence the enqueued commands in order to check for the
real calibration result.
- Perform autocalibration with self-check enabled.
- Only save/continue the wizard if autocalibration succeeds.
If during a paused print, the preheat is canceled, keep the bed target temperature
Display bed temperatures only if bed is also heated
Remove not needed variables nTargetOld and nTargetBedOld from the mFilamentItem function
Define new Setting "HeatBedOnLoad" [Yes/No]
There is no need to manually track the cursor position.
We can use the menu API:
MENU_BEGIN()
...
// menu items in between here
...
MENU_END()
Change in memory:
Flash: -116 bytes
SRAM: 0 bytes
Simplify the rendering to cover more scenarios:
"[nr.]>?"
"?>?"
Both of these indicate there is a bug in the firmware.
Currently these are not handled and result in the status screen being corrupted.
This is because we are trying to write a 3 digit number
where there is not space on the LCD for it.
Change in memory:
Flash: -52 bytes
SRAM: 0 bytes
It's only used when MESH_BED_LEVELING is not defined. According to
the configuration files, all printers supported use MESH_BED_LEVELING.
So I think we are safe in removing this dead code.
This code was introduced with v3.8.0 but was always disabled.
I propose the code be removed since it has not been enabled
for 3 years since its introduction.
We only need to check if the MMU is enabled once,
no need to do it in every submenu.
This way we save little bit of flash memory.
Change in memory:
Flash: -24 bytes
SRAM: 0 bytes
We can use lcd_print_pad to determine
whether the end of the file name was reached
lcd_print_pad now returns the last character pointed to.
If the end of the string was reached, it will be the null delimeter which
evaluates to "false" in an if statment (same as NULL).
Else "true" means the end of the string was not reached.
Change in memory:
Flash: -42 bytes
SRAM: 0 bytes
ON_MENU_ENTER runs code within the brackets only once
after a new menu is entered.
For the tool change menu, this allows us to display the data and
read from EEPROM only once.
Fixes#3715
When a long-press is triggered, the LCD inactivity timer
needs to be restarted. This is done with lcd_timeoutToStatus.start()
This also fixes situations where a long-press is triggered, and the timer
times out immediately (because it was not reset properly)
Change in memory:
Flash: +8 bytes
SRAM: 0 bytes
So in an ideal scenario, the newest file is first. This of course breaks as soon as a file is deleted/renamed/moved, but it should at least be fixed now compared to before where the direction could be influenced by a disabled setting
The current code forces any warning to return the user to the status
screen in order to show the message.
Thermal anomaly warnings can repeat at very short intervals, making menu
navigation (to pause/tune the print) impossible.
We now check if the message to be displayed is the same and only force a
kickback for new messages.
This partially reverts https://github.com/prusa3d/Prusa-Firmware/pull/3600
since we need the string to be null terminated for ease of comparison.
We pad the status line at display time instead using the new
lcd_print_pad() function which achieves the same effect.
In ultralcd_init() do not use lcd_setstatuspgm() to initialize the
welcome message.
The internal call to lcd_finishstatus() requires the serial to be
already available. Split the function into lcd_padstatus() to pre-pad