Commit Graph

59 Commits

Author SHA1 Message Date
Guðni Már Gilbert bc27b71729 Pull one common G1 gcode into PROGMEM
Change in memory:
Flash: -32 bytes
SRAM: 0 bytes
2023-03-18 17:37:27 +00:00
Guðni Már Gilbert 6edd8b0719 Add M220 into PROGMEM
Change in memory:
Flash: -10 bytes
SRAM: 0 bytes
2023-03-18 17:09:43 +00:00
Guðni Már Gilbert 00515a975d Add M107 into PROGMEM
Change in memory:
Flash: -4 bytes
SRAM: 0 bytes
2023-03-18 17:05:35 +00:00
Guðni Már Gilbert 5ade1716bf Add M500 into PROGMEM
Change in memory:
Flash: -6 bytes
SRAM: 0 bytes
2023-03-18 17:01:59 +00:00
Guðni Már Gilbert 733bc874fb Move G28W0 to messages
No change in memory
2023-03-18 16:48:30 +00:00
Guðni Már Gilbert 466a6a8fc3 Add M600 into PROGMEM
Change in memory:
Flash: -10 bytes
SRAM: 0 bytes
2023-03-18 16:33:13 +00:00
Guðni Már Gilbert 129cc18cbf Add M23 %s into PROGMEM
Change in memory:
Flash: -14 bytes
SRAM: 0 bytes
2023-03-18 16:18:05 +00:00
Guðni Már Gilbert 7c0ead7bc2 Add M24 into PROGMEM
Change in memory:
Flash: -8 bytes
SRAM: 0 bytes
2023-03-18 16:15:10 +00:00
Guðni Már Gilbert 5f8fc64a32 Restore previous Z-lift in M701/M702
Previously when the firmware called M701/M702 manually
there was no Z lift. But after we added support for the Z
parameter we set the default to 50mm.

Change strings "M701" to "M701 Z0" and "M702" to "M702 Z0"
to restore the previous behavior from before 3.13.

Also pulled the gcodes into PROGMEM in message.cpp
along with M83 and M84 to save memory.

Change in memory:
Flash: -34 bytes
SRAM: 0 bytes
2023-03-18 15:34:47 +00:00
3d-gussner e951a106d6 Messages fit to pages 2023-03-14 08:56:46 +01:00
3d-gussner 03778226ca Remove `Select Extruder:` message
Post fix PR4064 for update.po*.py scripts
2023-03-14 08:24:12 +01:00
3d-gussner 93598ef00d Change some messages to be max three rows instead of two
Yes|No are now located at the 4th row and so messages can
use three rows. This should allow improvement in some translations.
2023-03-14 08:23:40 +01:00
D.R.racer 5cd60636f9 Add missing translations + shorten to 16 chars 2023-02-18 17:39:30 +01:00
D.R.racer 98e7c15928 Change Eject filament -> Eject from MMU
PFW-1497
2023-02-18 17:39:30 +01:00
Guðni Már Gilbert 05662a5c0a optimsation: reduce code size in LCD rendering
Change in memory (MK3S+ Multilang):
Flash: -62 bytes
SRAM: -6 bytes
2023-02-18 16:32:08 +01:00
3d-gussner 8b1b632164 Fix copy/paste typo thanks to @gudnimg 2023-02-10 14:35:36 +01:00
3d-gussner 4f8dbb19fd Fix `M862.x` LCD messages
As the new menue adds a Yes/No option the messages
need to be limited to c=20 r=3
Updated/shortened all translations
2023-02-10 14:35:36 +01:00
3d-gussner ca978080c4 Change to Thermal model
Add prusa.io/tm-cal link
and update all TM related translations
2023-02-08 15:36:59 +01:00
Guðni Már Gilbert b28aa6f42a PFW-1471 Rename 'Toolchange count' to 'Material changes'
Added the string to our message so it can be translated

Change in memory:
Flash: -10 bytes
SRAM: 0 bytes
2023-02-06 08:33:40 +01:00
Yuri D'Elia dba3428ef2 Improve MSG_ACK_ERROR message 2022-12-17 20:25:47 +01:00
Yuri D'Elia f8290f25cd TM: Allow to resume without a running print
If there is no running print, and the printer is Stopped, add a new
"Acknowledge error" menu entry to unlock the printer.

This simply calls lcd_print_stop(), which is identical in behavior to a
thermal error with a running print.
2022-12-17 16:48:39 +01:00
3d-gussner 54ef2a6c28
Merge pull request #3769 from 3d-gussner/MK3_Temp_model_cal_wizard
PFW-1434: MK3 Temp model calibration during wizard
2022-11-30 15:33:38 +01:00
3d-gussner 32673e1681 Nozzle change menu 2022-11-23 11:39:26 +01:00
D.R.racer 4eaabbf092 Revive MMU stats + LCD screens 2022-11-20 17:27:36 +01:00
3d-gussner 281a217549 Update Temp Model messages
Deepl translate cs,de,es,fr,it,nl,pl
2022-11-20 10:49:46 +01:00
Guðni Már Gilbert 2096accc5f Remove unused gcode level check code
This code was introduced with v3.8.0 but was always disabled.
I propose the code be removed since it has not been enabled
for 3 years since its introduction.
2022-11-17 08:05:27 +01:00
Guðni Már Gilbert e11ef11a64 PFW-1425 Rename "Load to Extruder" to "Loading Test" 2022-11-16 06:00:15 +01:00
3d-gussner f2fe9a51ee rename `Extruder fan` to `Hotend fan` 2022-10-17 13:49:18 +02:00
Yuri D'Elia 1d3ee1caba build: Add Configuration_var.h as a configuration wrapper
Instead of including Configuration_prusa.h directly, include
Configuration_var which then includes the proper variant file though a
preprocessor macro.

This allows to keep the existing build system intact, but also redefine
at compile time the final header without having to make copies on the
file system.
2022-10-05 01:26:26 +02:00
3d-gussner 74e15ac233 Rename EN_ONLY to EN_FARM
remove DEBUG/DEVEL/ALPHA/BETA lcd warning
2022-09-29 16:39:02 +02:00
3d-gussner c7b500af1e BETA firmware message only in English
Rephrase BETA firmware message to fit on two screens
ALPHA message same as DEVEL
Fix ALPHA DEVEL message
2022-09-29 10:48:16 +02:00
3d-gussner 47d7ea5dfd Add MSG_LOAD_ALL and replace it a two loactions -10bytes flash 2022-09-17 16:36:09 +02:00
3d-gussner 539cdbfeea Lower MSG_ rows 2022-09-17 08:48:56 +02:00
3d-gussner 2ba863d8a5 Reuse MSG_IR_0x_OR_..
fix lowercase
remove todos
2022-09-16 17:23:38 +02:00
3d-gussner edad625cf7 RIP Bondtech long live the Extruder 2022-09-16 16:31:27 +02:00
3d-gussner 37cde856e9 Rename Auto_deplete to Spool_join
Fix some missing MSG_ c= r=
2022-09-16 16:25:47 +02:00
D.R.racer 2d98cae8bd Fixup MK3_MMU2 branch after rebase onto MK3 2022-09-16 11:08:03 +02:00
D.R.racer 09cb9c6ecd Fixup after rebase + discussion 2022-09-16 10:22:38 +02:00
D.R.racer 121d43f896 Add a Try-Load-to-Bondtech operation
PFW-1347
2022-09-16 10:22:38 +02:00
Alex Voinea 340bc87110 Checkpoint: jam detection 2022-09-16 10:20:32 +02:00
Alex Voinea d2bfe422f1 Separate runout and enabled settings 2022-09-16 10:17:04 +02:00
Alex Voinea 5484882758 Checkpoint after a lot of removal 2022-09-16 10:17:04 +02:00
3d-gussner f65e8ae5dd Add MSG_ALWAYS 2022-09-14 11:33:24 +02:00
3d-gussner 129b646c58 Fix MSG_ c=
Add MSG_ to messages.c/h
2022-09-14 11:33:24 +02:00
3d-gussner ee6821eb0e Add missing MSG_ c= r= 2022-09-14 11:33:24 +02:00
Yuri D'Elia 35c3e3ce68 Remove MSG_M117_V2_CALIBRATION
This message is never actually shown on the LCD (it's immediately
overwritten by other content). It also include g-code in a translatable
string, which is not a good idea. It's also otherwise identical to
MSG_V2_CALIBRATION, which we should have used.

Just remove it and save some space in the process.
2022-09-14 11:33:24 +02:00
Yuri D'Elia c7354bdfe8 lang: Fix usage of new non-translated strings
Fix cherry-pick
2022-09-14 11:33:24 +02:00
Yuri D'Elia 81238fbb15 Move MSG_PAUSED_THERMAL_ERROR outside TEMP_MODEL
MSG_PAUSED_THERMAL_ERROR is not specific to model-checking and can be
used also on MK25* variants.
2022-09-02 15:59:29 +02:00
Guðni Már Gilbert f7ae3039f8 Don't include M851 in build if Auto Bed Leveling is not enabled
The variable cs.zprobe_zoffset is not used unless
auto bed leveling is enabled
2022-08-26 15:35:28 +00:00
Yuri D'Elia 19df196e1f Better differentiation between pause/paused resume/resumed states
Use OCTOPRINT_ASK_* for the present form of actions. In these cases the
host will perform the pausing manouvers for us.

Use OCTOPRINT_* instead for the past tense forms when we are in charge.

Also always emit the action, whether we are or not sd-printing. This is
due to the new Stopped handling behaving correctly in either case.
2022-07-25 17:30:22 +02:00