as requested in Prusa-Error-Codes PR#97
There will be more separate sources of MCU power errors in the future and reporting each of them separately doesn't make much sense
- especially when the only thing a user can do about it is to check the connectors.
So based on this, the error title has changed a bit (we are not using the full text description in 8bit FW)
Also, update perform the related changes in PO files + add (machine generated) translations.
* Sync PEC `FINDA_DIDNT_GO_OFF` to `FINDA_FILAMENT_STUCK`
* Sync PEC `FSENSOR_DIDNT_GO_OFF` to `FSENSOR_FILAMENT_STUCK`
* Sync PEC `PULLEY_STALLED` to `PULLEY_CANNOT_MOVE`
* Sync PEC `SELECTOR_CANNOT_MOVE` update text
* Sync PEC `IDLER_CANNOT_MOVE` update text
* Sync PEC `PULLEY_WARNING_TMC_TOO_HOT` to `WARNING_TMC_PULLEY_TOO_HOT`
* Snyc PEC `RestartMMU` to `ResetMMU`
Also related text
* Sync PEC `SELECTOR_WARNING_TMC_TOO_HOT` to `WARNING_TMC_SELECTOR_TOO_HOT`
* Sync PEC `IDLER_WARNING_TMC_TOO_HOT` to `WARNING_TMC_IDLER_TOO_HOT`
* Sync PEC `PULLEY_TMC_OVERHEAT_ERROR` to `TMC_PULLEY_OVERHEAT_ERROR`
* Sync PEC `SELECTOR_TMC_OVERHEAT_ERROR` to `TMC_SELECTOR_OVERHEAT_ERROR`
* Sync PEC `IDLER_TMC_OVERHEAT_ERROR` to `TMC_IDLER_OVERHEAT_ERROR`
* Sync PEC `PULLEY_TMC_DRIVER_ERROR` to `TMC_PULLEY_DRIVER_ERROR`
Also releated text
* Sync PEC `SELECTOR_TMC_DRIVER_ERROR` to `TMC_SELECTOR_DRIVER_ERROR`
Also related text
* Sync PEC `IDLER_TMC_DRIVER_ERROR` to `TMC_IDLER_DRIVER_ERROR`
Also related text
* Sync PEC `PULLEY_TMC_DRIVER_RESET` to `TMC_PULLEY_DRIVER_RESET`
* Sync PEC `SELECTOR_TMC_DRIVER_RESET` to `TMC_SELECTOR_DRIVER_RESET`
* Sync PEC `IDLER_TMC_DRIVER_RESET` to `TMC_IDLER_DRIVER_RESET`
* Sync PEC `PULLEY_TMC_UNDERVOLTAGE_ERROR` to `TMC_PULLEY_UNDERVOLTAGE_ERROR`
* Sync PEC `SELECTOR_TMC_UNDERVOLTAGE_ERROR` to `TMC_SELECTOR_UNDERVOLTAGE_ERROR`
* Sync PEC `IDLER_TMC_UNDERVOLTAGE_ERROR` to `TMC_IDLER_UNDERVOLTAGE_ERROR`
* Sync PEC `PULLEY_TMC_DRIVER_SHORTED` to `TMC_PULLEY_DRIVER_SHORTED`
Also related text
* Sync PEC `SELECTOR_TMC_DRIVER_SHORTED` to `TMC_SELECTOR_DRIVER_SHORTED`
Also related text
* Sync PEC `IDLER_TMC_DRIVER_SHORTED` to `TMC_IDLER_DRIVER_SHORTED`
Also related text
* Sync PEC `PULLEY_SELFTEST_FAILED` to `MMU_PULLEY_SELFTEST_FAILED`
Also related text
* Sync PEC `SELECTOR_SELFTEST_FAILED` to `MMU_SELECTOR_SELFTEST_FAILED`
Also releated text
* Sync PEC `IDLER_SELFTEST_FAILED` to `MMU_IDLER_SELFTEST_FAILED`
Also related text
* Sync PEC fix MMU_MMU
Update MMU MCU UNDERPOWER
* Sync PEC `FIL_ALREADY_LOADED` to `FILAMENT_ALREADY_LOADED`
Also related text
* Add Prusa Error Codes check script
* Remove `:` at FINDA and FSENSOR as it is in other tiles
* Sync
FSENSOR_DIDNT_TRIGGER
MSG_DESC_SELECTOR_CANNOT_MOVE
MSG_DESC_IDLER_CANNOT_MOVE
MSG_DESC_FW_UPDATE_NEEDED
FILAMENT_ALREADY_LOADED
* Add MMU UNKOWN_ERROR PEC
This generates a warning under -Wextra, since in most cases a const
value doesn't prevent buggy code (as copies are allowed) while
preventing some optimizations (such as move operations) to take place.
This is a draft PR showing the potential 3x retry implementation on the printer's side.
It is much less code and looks more reliable than the same functionality in the MMU FW.
Still, more work needs to be done:
- [ ] Button is sent to the MMU even before returning from the parking position
- [ ] Then the button is sent again
- [ ] Then the printer runs out of retryAttempts
We need to find a better spot to check for "automatic" retry and issuing of the buttons
- Dependent on current MMU error being processed
- Includes rename of LEFT_BUTTON_CHOICE -> LCD_LEFT_BUTTON_CHOICE (and right, middle as well) to avoid confusion with MMU buttons' ordering
Such that:
MMU2:E=32766ErrorTitleTextDescription
Becomes:
MMU2:E=32766 ErrorTitle TextDescription
Also simplified the process of combining ErrorTitle and TextDescription
into the msg buffer by using snprintf. This is saver since we only
use dstSize in one place instead of two.
This could cause the printer to crash. The Serial Stream would show
a garbled string.
Also included in this commit:
* The buffer size is increased from 64 bytes to 192 bytes. We need to
take into account the length of the ErrorTitle and ErrorDescription.
* Fix overwrite in ErrorCode message buffer.